Estimating the Effect of Higher Order Modes in Spherical Near-Field Probe Correction


Authors: Allen Newell, Stuart Gregson
Publication: AMTA 2012
Copyright Owner: NSI-MI Technologies

The numerical analysis used for efficient processing of spherical near-field data requires that the far-field pattern of the probe can be expressed using only azimuthal modes with indices of μ = ±1. (1) If the probe satisfies this symmetry requirement, near-field data is only required for the two angles of probe rotation about its axis of χ = 0 and 90 degrees and numerical integration in χ is not required. This reduces both measurement and computation time and so it is desirable to use probes that will satisfy the μ = ±1 criteria. Circularly symmetric probes can be constructed that reduce the higher order modes to very low levels and for probes like open ended rectangular waveguides (OEWG) the effect of the higher order modes can be reduced by using a measurement radius that reduces the subtended angle of the AUT. Some analysis and simulation have been done to estimate the effect of using a probe with the higher order modes (2) – (6) and the following study is another effort to develop guidelines for the properties of the probe and the measurement radius that will reduce the effect of higher order modes to minimal levels. This study is based on the observation that since the higher order probe azimuthal modes are directly related to the probe properties for rotation about its axis, the near-field data that should be most sensitive to these modes is a near-field polarization measurement. This measurement is taken with the probe at a fixed (x,y,z) or (θ,φ,r) position and the probe is rotated about its axis by the angle 􀣑. The amplitude and phase received by the probe is measured as a function of the χ rotation angle. A direct measurement using different probes would be desirable, but since the effect of the higher order modes is very small, other measurement errors would likely obscure the desired information. This study uses the plane-wave transmission equation (7) to calculate the received signal for an AUT/probe combination where the probe is at any specified position and orientation in the near-field. The plane wave spectrum for both the AUT and the probe are derived from measured planar or spherical near-field data. The plane wave spectrum for the AUT is the same for all calculations and the receiving spectrum for the probe at each χ orientation is determined from the far-field pattern of the probe after it has been rotated by the angle χ. The far-field pattern of the probe as derived from spherical near-field measurements can be filtered to include or exclude the higher order spherical modes, and the near-field polarization data can therefore be calculated to show the sensitivity to these higher order modes. This approach focuses on the effect of the higher order spherical modes and completely excludes the effect of measurement errors. The results of these calculations for different AUT/probe/measurement radius combinations will be shown.

View the paper