Calibration Range

Calibration Range

Description

The Calibration Test Range is a general purpose 20' x 30' x 15' anechoic test chamber. Typical frequencies of operation are from 1 to 40 GHz. Typical antenna sizes tested in this range can be as large as 6’ (2m) depending on test application. This range is primarily used for gain calibration of antennas using the three-antenna method or gain substitution method. The facility can accommodate Planar Near-Field Measurements utilizing a 3' x 3' X-Y scanner.

  • General Features

    • Multi-purpose Near-Field and Calibration
      • Planar or Spherical Near-Field Measurements
      • Gain Substitution and 3 Antenna Gain Calibrations
    • Utilizes MI-3000 Arena™ Software
    • Measurements up to 110 GHz

    PHYSICAL CHARACTERISTICS

    Frequency Range 1 – 40 GHz
    Size 20 ft (w) x 30 ft (l) x 15 ft (h)
    (6.1 m x 9.1 m x 4.5 m)
    Max AUT Test Load 1,000 lbs (453.5 kg)
    Data Acquisition MI-3000 Arena™ Software Suite
    Cylindrical Quiet Zone 2 ft (0.6 m)
    Laser & Optical Alignment Precise to ± 0.001 in. ± 0.001 deg