2015 Technical Papers

A Calibration Method Using Interpolation to Reduce Measurement Errors in Electromagnetic Compatibility Measurements

Authors: Vince Rodriguez, Dennis Lewis
Publication: AMTA 2015
Copyright Owner: NSI-MI Technologies, The Boeing Company

MIL STD 461 is the Department of Defense standard that states the requirements for the control of electromagnetic interference (EMI) in subsystems and equipment used by the armed forces. The standard requires users to measure the unintentional radiated emissions from equipment by placing a measuring antenna at one meter distance from the equipment under test (EUT). The performance of the antenna at 1m distance must be known for the antenna to measure objects located at this close proximity. MIL STD 461 requires the antennas to be calibrated at 1 m distance using the Society of Automotive Engineers (SAE) Aerospace Recommended Practice (ARP) 958. This SAE ARP 958 document describes a standard calibration method where two identical antennas are used at 1m distance to obtain the gain at 1m for each antenna. In this paper the authors show using simulations that the SAE ARP 958 approach introduces errors as high at 2 dB to the measured gain and AF. To eliminate this problem the authors introduce a new method for calibrating EMC antennas for MIL STD 461. The Method is based on the well-known extrapolation range technique. The process is to obtain the polynomial curve that is used to get the far field gain in the extrapolation gain procedure, and to perform an interpolation to get the gain at 1 m. The results show that some data in the far field must be collected during the extrapolation scan. When the polynomial is calculated the antenna performance values at shorter distances will be free of near field coupling. Measured results for a typical antenna required for emissions testing per the MIL STD 461 match well with the numerical results for the computed gain at 1 m distance. Future work is required to study the use of this technique for other short test distances used in other electromagnetic compatibility standards, such as the 3 m test distance used by the CISPR 16 standard.

Atlanta

1125 Satellite Blvd. NW,
Ste. 100
Suwanee, GA 30024 USA

+1 678 475 8300
+1 678 542 2601

Los Angeles

19730 Magellan Dr.
Torrance, CA 90502 USA

+1 310 525 7000
+1 310 525 7100

NSI-MI UK

C/O AMETEK LAND,
Stubley Lane,
Dronfield, S18 1DJ UK

+44 1246 581500

SIAE International Airshow

Paris, France Finding your local time... 10 Days www.siae.fr
This site is using cookies for analytical purposes and to provide a better user experience. Read our Privacy Policy for more information.