Anechoic Chamber Diagnostic Imaging

Authors: Greg Hindman, Dan Slater
Publication: AMTA 1992
Copyright Owner: NSI-MI Technologies

Traditional techniques for evaluating the performance of anechoic chambers, compact ranges, and far-field ranges involve scanning a field probe through the quiet zone area. Plotting the amplitude and phase ripple yields a measure of the range performance which can be used in uncertainty estimates for future antenna tests. This technique, however, provides very little insight into the causes of the quiet-zone ripple. NSI's portable near-field scanners and diagnostic software can perform quiet-zone measurements which will provide angular image maps of the chamber reflections. This data can be used by engineers to actually improve the chamber performance by identifying and suppressing the sources of high reflections which cause quiet-zone ripple.

 