An Implementation of the Three Cable Method

Author: O. M. Caldwell
Publication: AMTA 1992
Copyright Owner: NSI-MI Technologies

The three cable method for removing the amplitude and phase variations of microwave cables due to temperature change and movement can offer a substantial improvement in antenna measurement accuracy. Implementation details of the method are provided for a planar near-field range. Items specifically addressed are range configuration, hardware requirements, data collection methodology, identification and assessment of error sources, and data requirements.

 